Explore DELMER industrial water chillers for temperature-controlled process cooling across compatible induction melting furnaces, induction heating systems, continuous casting machines and precious-metal casting equipment. Correct cooling capacity, flow, pressure and water temperature are essential for reliable equipment operation.
Chiller selection depends on the connected machine's heat load, power rating, duty cycle, cooling-circuit design, ambient temperature and installation conditions. Specifications and compatibility should be confirmed for the exact equipment model before ordering.
How to select a chiller
- Confirm required cooling capacity and operating duty.
- Verify water flow rate, pressure, inlet/outlet connections and temperature range.
- Check electrical supply, refrigerant and site ventilation requirements.
- Confirm whether the equipment requires a closed-loop chiller or another cooling arrangement.
Contact DELMER with your machine model and operating requirements for application matching and technical confirmation.
- Description
- Ask a question
- Review
DELMER High-Capacity Industrial Water Chiller
A high-capacity process-cooling solution for compatible industrial machinery and casting equipment. With a stated cooling capacity of 69,000 kcal/h (approximately 80 kW or 22.8 TR), this unit is intended for applications with substantially higher heat loads than compact process chillers. Final suitability must be confirmed against the connected machine's cooling requirements.
Published specifications
- Cooling capacity: 69,000 kcal/h (approximately 80 kW / 22.8 TR)
- Electrical supply: 380 V, 50/60 Hz, three-phase
- Stated water outlet temperature: 22°C
- Refrigerant: R410, as listed in the current product specification
- Compressors: Two 9 kW compressors (2 × 9 kW), as listed in the current product specification
Potential applications
- Compatible gold and silver casting equipment
- Industrial process machinery requiring high-capacity water cooling
- Compatible induction melting and induction heating systems
- Other process applications where the required cooling load and operating conditions match the unit
System matching is essential
Cooling capacity alone does not establish compatibility. Before ordering, confirm the machine's heat-rejection load, required inlet and outlet water temperatures, flow rate, operating pressure, duty cycle, connection sizes, installation arrangement and electrical requirements. Confirm the exact condenser configuration and refrigerant details against the unit documentation.
DELMER can help review your equipment model and process requirements to determine whether this chiller is appropriate. Installation, electrical connection and commissioning should be completed by qualified technicians.
- Description
- Ask a question
- Review
DELMER 1.5 TR Industrial Water Chiller
Compact process-water cooling for compatible induction furnaces and other industrial equipment requiring a controlled recirculating cooling circuit. The DELMER 1.5 TR chiller provides a nominal cooling capacity of 1.5 refrigeration tons (approximately 5.2 kW) and an insulated 150-litre stainless-steel water tank.
Key specifications
- Nominal cooling capacity: 1.5 TR / approximately 5.2 kW / 18,000 BTU/h
- Tank: 150-litre insulated tank, SS 304 stainless steel
- Temperature control: Digital controller; stated range +5°C to +25°C, ±1°C
- Evaporator: Copper coil located in the tank
- Condenser: Air-cooled with axial fan
- Circulation pump: 0.5 HP stainless-steel centrifugal monoblock pump
- Refrigerant: R-407C; manual states 1,450 g
- Electrical supply: Specification table states 415 V AC, 3-phase + neutral, 50 Hz; rated current 5 A
- Water connections: 1/2-inch BSP inlet and outlet
Applications
For compatible induction melting furnaces, induction heating equipment and industrial process applications where the required cooling load falls within the chiller's capacity. Suitability depends on machine power, heat rejection, duty cycle, required water temperature, flow and pressure.
Installation and maintenance
Install on a level, load-bearing surface with unobstructed condenser airflow. The manual recommends approximately 1 metre of clearance at condenser air intake and discharge faces. Regularly inspect and clean the return-line Y-strainer and condenser coil. Installation and electrical work must be performed by qualified personnel.
Confirm before ordering
The manual contains inconsistent voltage guidance in its installation section. The specification table lists 415 V AC, 3-phase + neutral, 50 Hz; verify the actual unit nameplate and site supply before installation. Please also confirm required flow, pressure, connections and cooling capacity against your exact furnace or machine model with DELMER.