{"product_id":"moisture-analyser-balances","title":"Delmer MB-Series Halogen Moisture Analyser","description":"\u003ch2\u003eDelmer MB-Series Halogen Moisture Analyser\u003c\/h2\u003e\u003cp\u003eThe Delmer MB-Series is a range of halogen-heated moisture analysers for measuring sample mass loss during a controlled heating process and calculating moisture content according to the instrument's method. Model choice depends on sample mass, moisture range, material behaviour, required reporting increment and the test method. Results are method-dependent; validate settings for the material and intended use.\u003c\/p\u003e\u003ch3\u003eListed model specifications\u003c\/h3\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eModel\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMass readability\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMoisture display increment\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eRepeatability, 2 g sample\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eRepeatability, 10 g sample\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMB 40\u003c\/th\u003e\n\u003ctd\u003e40 g\u003c\/td\u003e\n\u003ctd\u003e1 mg\u003c\/td\u003e\n\u003ctd\u003e0.001%\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003ctd\u003e0.03%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMB 50\u003c\/th\u003e\n\u003ctd\u003e50 g\u003c\/td\u003e\n\u003ctd\u003e1 mg\u003c\/td\u003e\n\u003ctd\u003e0.001%\u003c\/td\u003e\n\u003ctd\u003e0.05%\u003c\/td\u003e\n\u003ctd\u003e0.02%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMB 120\u003c\/th\u003e\n\u003ctd\u003e120 g\u003c\/td\u003e\n\u003ctd\u003e1 mg\u003c\/td\u003e\n\u003ctd\u003e0.001%\u003c\/td\u003e\n\u003ctd\u003e0.05%\u003c\/td\u003e\n\u003ctd\u003e0.02%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMB 200\u003c\/th\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003ctd\u003e1 mg\u003c\/td\u003e\n\u003ctd\u003e0.001%\u003c\/td\u003e\n\u003ctd\u003e0.05%\u003c\/td\u003e\n\u003ctd\u003e0.02%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMB 54\u003c\/th\u003e\n\u003ctd\u003e50 g\u003c\/td\u003e\n\u003ctd\u003e1 mg\u003c\/td\u003e\n\u003ctd\u003e0.0001%\u003c\/td\u003e\n\u003ctd\u003e0.005%\u003c\/td\u003e\n\u003ctd\u003e0.015%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003cstrong\u003eListed pan diameter:\u003c\/strong\u003e 95 mm for the range. Confirm model-specific specifications against the current datasheet before ordering.\u003c\/p\u003e\u003ch3\u003eApplications for moisture testing\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eIncoming-material inspection and routine quality control\u003c\/li\u003e\n\u003cli\u003eFood and agricultural materials, powders and granulates, where a validated method is appropriate\u003c\/li\u003e\n\u003cli\u003eChemicals and industrial raw materials\u003c\/li\u003e\n\u003cli\u003eResearch and process checks that require repeatable moisture-content measurements\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThese are potential application categories, not a guarantee that every material can be tested with the same settings. Heat-sensitive, volatile, crust-forming or chemically reactive samples may require a different method or specialist safety review.\u003c\/p\u003e\u003ch3\u003eHow to choose an MB-Series model\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm sample mass:\u003c\/strong\u003e keep the expected sample within the model's listed capacity and the method's recommended sample size.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDefine reporting needs:\u003c\/strong\u003e distinguish mass readability from the moisture display increment and from method accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValidate temperature and time:\u003c\/strong\u003e establish a suitable heating profile and endpoint for the specific material; do not rely on one generic programme for all samples.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck repeatability:\u003c\/strong\u003e compare the listed repeatability conditions with your sample mass and acceptance limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm documentation and connectivity:\u003c\/strong\u003e request details of temperature range, timer, endpoint modes, data output, calibration, software and included accessories for the exact model.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eGood moisture-testing practice\u003c\/h3\u003e\u003cp\u003ePrepare a representative, homogeneous sample; use consistent sample mass and distribution; keep the sample pan clean; avoid unnecessary exposure to ambient humidity; and document the method, temperature, endpoint and sample preparation. Compare results with an appropriate reference method during method development or where required by the quality system.\u003c\/p\u003e\u003cp\u003eThe displayed increment is not the same as method accuracy. Repeatability depends on model, sample mass, sample properties and test conditions. The listing does not imply automatic compliance with a particular food, pharmaceutical or industrial standard.\u003c\/p\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does a halogen moisture analyser measure?\u003c\/strong\u003e It estimates moisture content from mass change during heating according to the configured method; the result depends on sample preparation and test settings.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich model should I select?\u003c\/strong\u003e Compare capacity, moisture display increment, sample mass and repeatability. Confirm the datasheet and test method for the exact model.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it test food, feed or pharmaceutical samples?\u003c\/strong\u003e It may be used where the method is suitable and validated for the material. Verify relevant safety, quality-system and regulatory requirements before routine testing.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat details help Delmer recommend a configuration?\u003c\/strong\u003e Provide the sample material, expected moisture range, typical sample mass, target test time or throughput, required method and destination country.\u003c\/p\u003e\u003cp\u003eExplore the \u003ca href=\"\/gu\/collections\/jewellery-scale\"\u003eDelmer Laboratory \u0026amp; Jewellery Scales collection\u003c\/a\u003e or \u003ca href=\"\/gu\/pages\/contact\"\u003econtact Delmer Group\u003c\/a\u003e for model selection, current datasheets and a quotation. International delivery and support options should be confirmed for your destination.\u003c\/p\u003e","brand":"Delmer Group","offers":[{"title":"Default Title","offer_id":41367047143517,"sku":"","price":450000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0299\/3163\/4781\/files\/Capture6_bb0035e1-a233-493f-acdf-a53303618ad1.png?v=1702035031","url":"https:\/\/delmergroup.com\/gu\/products\/moisture-analyser-balances","provider":"Delmer Group","version":"1.0","type":"link"}